control center

The control center supervises
and directs the facility.
 
Technische Daten
Incineration max. energy input 24.2 MW
Design of the Incineration system with a throughput of 5 t waste per hour with an average calorific value of 17.4 MJ/kg and a minimum availability of 7000 operating hours p.a., the annual capacity is 35,000 t
Rotary kiln
outer diameter4.7 m
inner diameter4.1 m
length12.0 m
tilt3 degrees
temperature950 - 1,200 °C
Secondary combustion chamber
outer diameter6.6 m
inner diameter5.4 m
height15 m
temperature> 1,100 °C
flue gas dwell time> 2 sec.
Steam generator
steam quantity
at 320°C/40 bar    
 
   28 t/h
Energy
generation
 
   max. 4.5 MW electricity
Flue gas cleaning system 7-stage wet/dry process
 