The flue gas cleaning system

The flue gas cleaning system
Verantwortung für die Umwelt

E m i s s i o n   D a t a

The following table lists the limits laid down in the 17th Directive pursuant to the Federal Law on Protection from Emission (17th BlmSchV) and in the SAVA Planning Resolution (PR), given as average daily values against the actual annual and monthly averages.

Parameters Unit

Emission limit
17. BlmschV

Emission limit
PR
Actual annual mean 2011 Actual monthly mean
April 2012
Carbon-
monoxide
mg/m³ 50 50 2.79 0.42
Particulates mg/m³ 10 5 0.57 0.49
Total carbon mg/m³ 10 5 0.36 0.41
Hydrochloric acid mg/m³ 10 5 0.36 0.51
Sulphur oxides mg/m³ 50 25 2.01 0.07
Nitrogen oxides mg/m³ 200 100 76.11 52.87
Mercury mg/m³ 0.03 0.03 0.0052 0.0066



The flue gases are checked for their content of heavy metals, hydrofluoric acid, dioxins and furans once each year in a monitoring campaign. The current results are listed below:

Parameters Unit Limits Annual measurement 2012
Hydrofluoric acid mg/m³ 1.0 < 0,2
Total cadmium and thallium mg/m³ 0.05 0.002
Total antimony, arsenic, lead, chromium, cobalt, copper, manganese, nickel, vanadium, tin mg/m³ 0.50 0.025
Total arsenic, benzo[a]pyrene, cadmium, cobalt and chromium mg/m³ 0,05 0.004
Dioxins und furans as TE* ng/m³ 0.10 0.002
 
*The toxicity equivalent TE is a total figure for the assessment of the total toxicity of all dioxins and furans
SAVA GmbH & Co. KG
Ostertweute 1, 25541 Brunsbüttel
Tel.: +49(0)4852/8308-0, Fax: +49(0)4852/8308-12, e-mail: info.sava@remondis.de